Add to Cart
Specification
| 1 | 200mm tube door leaf frame | ||
| 2 | top guide wheel | ||
| 3 | top guide wheel pad | ||
| 4 | top guide wheel screw | ||
| 5 | bottom wheel | ||
| 6 | bottom wheel bracket | ||
| 7 | 12A chain | ||
| 8 | driving gear | ||
| 9 | Motor shaft | ||
| 10 | Motor fixing bracket | ||
| 11 | Bottom cover | ||
| 12 | ground rail | ||
| 13 | Splint | ||
| 14 | Splint screw | ||
| 15 | 50 angle iron | ||
| 16 | Angle iron embedded screw | ||
| 17 | Drainage frame | ||
| 18 | Drain grate | ||
| 19 | Door stop | ||
| 20 | Top rail | ||
| 21 | square tube hanging parts | ||
| 22 | leaf panel | ||
| 23 | U-shaped channel steel | ||
| 24 | trolley wire | ||
| 25 | Trolley wire bracket | ||
| 26 | Collector wire | ||
| 27 | Collector bracket | ||
| 28 | Side seal | ||
| 29 | Safty Protection System | ||
| 30 | ABB Motors | ||
| 31 | control box | ||
Design wind load according to typhoon level
Typhoon:
Level 12 is 32.4-36.9 m/s;
Level 13 is 37.0-41.4 m/s;
Level 14 is 41.5-46.1 m/s,
Level 15 is 46.2-50.9 m/s,
Level 16 is 51.0-56.0 m/s,
Level 17 is 56.1-61.2 m/s.
For any door member ,the deflection due to design wind load not exceed the member's length divided by 150.
Design Doors as a system to withstand the upward and downward deflections of the door header structure .